DSC 22.2 GLM DUOBLOC mixed gas to oil burner with mechanical modulating control Epsylon series

SC. 22.2 GLM

Power Kw/h Min 7000
Max 35000
Kcal/h Min
Max
Supply voltage
Engine
Valve diameter

More information

Modulating burners with electronic regulation regulation represent an evolution of the traditional mechanical type adjustment system towards a digital type system.
The servomotors of each of the air, gas and liquid fuel flow adjustment devices respond to orders from a microprocessor in which the parameter curves defined for each of these elements have been recorded.

  1. Duoblock burners with high temperature steel housing and combustion head.
  2. The following fuels may be used:
    Natural gas, PCI 6.99 … 11.39 kWh/m3; LPG, PCI 25.89 kWh/m3; Biogas
    Heavy oil, viscosity 50°E at 50°C, PCI 10.97 kWh/kg
  3. It is suitable for steam, hot water boiler, furnaces, dryers, thermal oil generators, etc.
  4. Each burner can be customized to the needs of the installation.
  5. Digital programming is done on the screen or using a computer, and following the simple instructions.
  6. The additional advantage offered by the system lies in the precise knowledge of all the commands and all the states of the system as a whole.
  7. In addition, the microprocessor system also performs the following functions:
  8. Control and monitoring of the burner start-up and operation phases, with the possibility of configuring the set modes and times;
  9.  Flame control, with different monitoring devices, for intermittent or continuous operation (more than 24 hours);
  10. Integrated gas valve check system checks for leaks at each burner cycle for added safety
  11. Up to 15 programmable points for each air-fuel ratio curve
  12. Access levels are protected by specific passwords corresponding to the different types of users (viewing by customer, programming by technician, etc.).
  13. The system can be completed by integrating it with a system of automatic adjustment of excess air by oxygen sensor with action on the position of the air damper.
  14. Up to 15 programmable points for each air-fuel ratio curve
  15. Access levels are protected by specific passwords corresponding to the different types of users (viewing by customer, programming by technician, etc.).
  16. The system can be completed by integrating it with a system of automatic adjustment of excess air by oxygen sensor with action on the position of the air damper.
  17. Finally the fan speed adjustment system with variable speed drive to ensure maximum energy savings, both fuel and electrical energy.
  18. Standard protection of mechanical parts IP 54.
  19. IP 65 protection on request.
  20. The flame can be adjusted according to the combustion chamber.
  21. Compliance with the following directives:
    2014/35/EU Low Voltage Directive
    2014/30/EU EMC Directive
    2006/42/EC Machinery Directive
    2011/65/EU RoHS2 Directive
    2016/426/EU Gas Appliance Regulation
en_USEnglish