SC 5.1 LM MONOBLOC modulating oil burner RANGE
SC. 5.1 LM |
|||||
---|---|---|---|---|---|
Power | kW/h | Min | 200 | ||
Max | 750 | ||||
kcal/h | Min | 172.000 | |||
Max | 654.000 | ||||
l/h | Min | 16 | |||
Max | 63 | ||||
Feeding | 3N-50 Hz 380V | ||||
Engine kW | 0,75 | ||||
Pump Motor kW | 0,37 | ||||
Gas Inlet Pressure mbar | 21-300 |
Category: Oil Burners
More information
- Duoblock burners with high temperature steel housing and combustion head.
- The following fuels can be used: Light oil, viscosity 6 mm2/s at 20°C, PCI11.86 kWh/kg
- It is suitable for steam, hot water boiler, furnaces, dryers, thermal oil generators, etc.
- Each burner can be customized to the needs of the installation.
- Reduction of intervention time during maintenance operations:
Electrical components with plug-in connectors
Full accessibility to the aeraulic circuit and combustion head
- Flame control is simple and reliable thanks to the photocell.
- A customized type of sensor is used for sequential installation of multiple generators.
- The ease of design and the use of preheated combustion air while allowing energy savings by increasing the efficiency of the combustion economizer used by the system.
- It has the characteristics of good performance in different combustion chambers.
- It minimizes the specific amount of nitric oxide (NOx) gas emission by obtaining an optimal fuel air mixture thanks to the customized design of its combustion head.
- It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions.
- Allows operation in high back pressure combustion chambers by placing a high pressure venting system.
- Standard protection of mechanical parts IP 54.
- IP 65 protection on request.
- Optional internal or external flue gas circulation to reduce NOx emissions.
- Includes all cables and power supply for the burner management system.
- The flame can be adjusted according to the combustion chamber.
- The incorporation of a high pressure fan allows working in combustion chambers with high back pressures.
Compliance with the following directives:
- 73/23/EEC
- 98/37/EEC
- 90/396/EEC
- EN 676
OPTIONS
- Continuous O2 analyzer to provide extra efficiency.
- Continuous CO analyzer for a sensitive control system.
- Variable speed drive
- IP 65 protection on request.
- Possibility to select the premixing head for low NOx.
- Internal or external recirculation of combustion gases for low emissions.
- Simultaneous combustion.
- Soundproof fan.