SC 11.3 GMN - Pneumatic modulating gas regulation

SC. 11.3 GMN

Power Kw/h Min 1250
Max 5000
kcal/h Min 1.075.000
Max  4.300.000
Supply Voltage 3N - 50 Hz 380V
Engine kW 7.5
Valve diameter 300 mbar DN 50
Category:

More information

Monobloc burners with pneumatic mechanical modulating modulating power adjustment

  1. Duoblock burners with high temperature steel housing and combustion head.
  2.  The following fuels may be used:
    • Natural gas, PCI 6.99 ... 11.39 kWh/m3;
    • LPG, PCI 25.89 kWh/m3
    • Biogas
  3. It is suitable for steam, hot water boiler, furnaces, dryers, thermal oil generators, etc.
  4. Each burner can be customized to the needs of the installation.
  5. The ease of design and the use of preheated combustion air while allowing energy savings by increasing the efficiency of the combustion economizer used by the system.
  6.  Flame control, with different monitoring devices, for intermittent or continuous operation (more than 24 hours);
  7. Standard protection of mechanical parts IP 54.
  8. IP 65 protection on request.
  9. The flame geometry can be adjusted according to the combustion chamber.
  10. The modulation ratio is 1/6
  11.  Compliance with the following directives:
    • 89/336 (2004/108) EEC
    • 73/23/EEC
    • 98/37/EEC
    • 90/396/EEC
    • EN 676

OPTIONS

  • IP 65 protection on request.
  • Possibility to select the premixing head for low NOx.
  • Soundproof fan