PRODUCTS
SC 8.3 GZ Natural gas burners monobloc Two Stage
Technical information

SC. 8.3 GZ

Capacity

Kw/hMin580
Max2100
kcal/hMin498.800
Max1.806.000

m3/h

Min60
Max218
Power Supply3N-50 Hz 380V
Motor Kw3
Gas Input Pressure
21-300
More information 1. Natural gas, propane, biogas can be used.
2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc.
3. The flame can be adjusted according to the combustion chamber.
4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation.
5. The 1/ 5 regulation of the electronic modulation power, is really advantageous compared to our rivals.
6. Flame monitoring is easy and reliable thanks to the UV sensor.
7. A customized type of sensor is used for sequentially installment of several generators.
8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system.
9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power.
10. It has the characteristics of proper functioning in different combustion chambers.
11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood.
12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions.
13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system.
14. Ease of installation of the gas train to the burner.
15. The possıbılıty of selectıng the premix hood as Low Nox.
16. Standard protection of IP 54 mechanical parts.
17. IP 65 protection on demand.
18. Internal or external optional circulation of combustion gases in order to reduce NOx emissions.
19. It includes all the cables and power supply of the burner management system.
20. Includes impermeability control.
21. Compliance with the following directives:
89/336(2004/108)EEC
73/23/EEC
98/37/EEC
EN 676
22. Continuous O2 analyzer in order to sustain extra efficiency.
23. Continuous CO analyzer for precise control system.
24. Speed variant to extend product life cycle.
25. IP 65 protection on demand.
26. The possıbılıty of selectımg the premix hood for Low Nox
27. Internal or external re-circulation of combustion gases for low emissions.
28. Simultaneous combustion
29. Sound insulated ventilation system







All Rights Reserved. 2018 Flamtec. | Miembros del gremio de instaladores | Aviso legal