PRODUCTS
SC 16.1 GM Natural gas burners duobloc electronic modulation Epsilon
Technical information

SC. 16.1 GM

CapacityKw/hMin1300
Max10.500
kcal/hMin1.118.000
Max9.030.000

m3/h

Min135
Max1094
Power Supply3N-50 Hz 380V
Motor Kw
22
Gas Input Pressure21-300
More information 1. Natural gas, propane, biogas can be used.
2. It is suitable for steam, hot water boiler, ovens, driers, heat oil generators, etc.
3. The flame can be adjusted according to the combustion chamber.
4. Burning hood, ventilation system, control panel, gas pipe could be selected according to special conditions of each installation.
5. The 1/ 7 regulation of the electronic modulation power, is really advantageous compared to our rivals.
6. Flame monitoring is easy and reliable thanks to the UV sensor.
7. A customized type of sensor is used for sequentially installment of several generators.
8. The facility of heating and the use of preheated combustion air while enabling energy saving in increasing the efficiency of the burning through economiser used by the system.
9. It enables flame control at each point between minimum and maximum power. It enables flame control at each point between minimum and maximum power.
10. It has the characteristics of proper functioning in different combustion chambers.
11. Reduces the specific emission amount of nitric oxide (NOx) gas to a minimum by obtaining an optimum mixture of combustible air thanks to the customized design of its combustion hood.
12. It provides easy installation and operating conditions in confined spaces thanks to its compact dimensions.
13. It enables operation in high backpressure combustion chambers by placing a high-pressure ventilation system.
14. Ease of installation of the gas train to the burner.
15. The possıbılıty of selectıng the premix hood as Low Nox.
16. Standard protection of IP 54 mechanical parts.
17. IP 65 protection on demand.
18. Internal or external optional circulation of combustion gases in order to reduce NOx emissions.
19. It includes all the cables and power supply of the burner management system.
20. Includes impermeability control.
21. Compliance with the following directives:
89/336(2004/108)EEC
73/23/EEC
98/37/EEC
EN 676
22. Continuous O2 analyzer in order to sustain extra efficiency.
23. Continuous CO analyzer for precise control system.
24. Speed to extend product life cycle.
25. Internal or external re-circulation of combustion gases for low emissions.
26. Simultaneous combustion
27. Sound insulated ventilation system




All Rights Reserved. 2018 Flamtec. | Miembros del gremio de instaladores | Aviso legal